Supplied directly by us · CT Scanner
512-Slice CT Scanner
Model SP-MD-004 · our reference
512-slice ultra-premium CT with 16 cm detector coverage and 0.259 s rotation
Overview
The SP-MD-004 Medical's 512-slice ultra-premium CT, approved by China's NMPA in 2020 as the country's first 512-slice panoramic multimodal CT. Its 16 cm Pano-spherical detector and 0.259 s gantry rotation enable one-beat, free-breathing coronary CTA and single-rotation spectral imaging. It is positioned for high-end cardiac, neurological and emergency imaging in tertiary hospitals.
Key highlights
- 512-slice wide-body CT with a 16 cm Z-axis Pano-spherical detector
- 0.259 s gantry rotation supports one-beat cardiac imaging in about 0.2 s
- One-beat whole-heart coverage of 160 mm at heart rates of 103-155 bpm
- Spectral imaging yields 161 single-energy images per rotation
- 60 kV low-dose scanning with a 30 MHU-equivalent wide-coverage tube
- Whole-body systemic vascular examination completed within 5 seconds
Technical parameters
14 published parameters, grouped.
Imaging
| Slice count | 512 slices |
|---|---|
| One-beat cardiac scan time | 0.2 s |
| Temporal resolution | 25 ms |
| One-beat whole-heart coverage | 160 mm |
| Heart rate range (one-beat cardiac) | 103-155 bpm |
| Whole-body systemic vascular examination | within 5 s |
| Spectral single-energy images per rotation | 161 |
| Visual spatial resolution | 0.17 mm |
Detector
| Z-axis detector coverage | 16 cm Pano-spherical detector |
|---|
Gantry
| Gantry rotation time | 0.259 s/rotation |
|---|---|
| Axial volume coverage per rotation | 16 cm |
Dose
| Minimum tube voltage | 60 kV |
|---|
Power
| X-ray tube heat capacity | 30 MHU equivalent |
|---|
Regulatory
| NMPA registration | 国械注准20203060462 (Class III, valid to 2030-05-07) |
|---|
Applications
- 1Coronary CT angiography at high or irregular heart rates without heart-rate control
- 2Acute chest pain triple-rule-out (coronary, pulmonary artery and aorta)
- 3One-stop stroke imaging (brain perfusion plus carotid/cerebral CTA)
- 4Low-dose lung cancer screening using 60 kV protocols
- 5Spectral / dual-energy imaging for gout, renal stones and tumour characterization
- 6Whole-body trauma and systemic vascular CTA (aorta plus lower limbs)
- 7Paediatric and other low-dose examinations
- 8Oncology staging and radiotherapy planning
Application video
No application video published yet.
We record application walk-throughs for buyers on request — ask us for a live demo or a custom video of this product in operation.
Request an application videoHow we supply this product
We are a China-based export and sourcing company. This product is supplied by us under our own programme — we buy it from the production base, inspect it, and ship to you. It is not sold to you through any third party.
Quote & specification
Send quantity, destination and certification needs. We confirm the exact configuration, voltage/plug variant and lead time.
Sample & approval
Sample or golden sample for your sign-off; private-label branding, packaging and manual localisation if you need them.
Inspect & ship
Pre-shipment inspection against the agreed specification, then consolidation and shipment on EXW / FOB / CIF / DDP terms.
Need a different configuration, voltage or volume? Send the requirement — we source beyond this catalogue.
Specification verification
Parameters on this page were compiled from production-base technical documentation and verified on 12 Sept 2026, at medium confidence. Specifications can change without notice — confirm the current revision with us before ordering. Detailed technical files are available on request.