Digital PET/CT with 189 ps TOF, 2.9 mm NEMA PET resolution and 28/35 cm axial FOV
Overview
The SP-MD-007 Imaging's next-generation digital PET/CT built on the platform. It combines 2.9 mm NEMA PET spatial resolution and 189 ps time-of-flight performance with a fully diagnostic 160-slice CT, positioning it as a premium clinical and research scanner. A scalable 28 cm / 35 cm axial PET field of view, 76 cm bore and 318 kg table capacity support oncology, cardiology, neurology and theranostic imaging.
Key highlights
- 189 ps time-of-flight resolution for higher PET contrast at lower dose
- 2.9 mm NEMA PET spatial resolution at 1 cm; 3.2 mm at 10 cm
- Scalable PET axial field of view of 28 cm or 35 cm on the same platform
- 76 cm wide bore with up to 318 kg (700 lb) table capacity
- 160-slice CT with 0.25 s rotation and 0.22 mm spatial resolution
- Effective PET sensitivity up to 259.3 cps/ on the 35 cm NEMA phantom
Technical parameters
25 published parameters, grouped.
Gantry
| Gantry aperture (bore) | 76 cm (30 inch) |
|---|---|
| Cooling method | Water cooling |
| Maximum rotation speed | 0.25 s |
Table
| Table weight capacity | Up to 318 kg (700 lb) |
|---|
Detector
| PET crystal material | LYSO |
|---|---|
| PET crystal size | 2.76 mm x 2.76 mm x 18.1 mm |
| coverage | 100% coverage of the LYSO array |
| CT detector rows / collimation | 80 rows, 0.5 mm x 80 with 3D collimator grid up to 160 slices/rotation |
Imaging
| PET NEMA spatial resolution @1 cm | 2.9 mm |
|---|---|
| PET NEMA spatial resolution @10 cm | 3.2 mm |
| PET time-of-flight (TOF) resolution | 189 ps |
| Scalable PET axial field of view | 28 cm, 35 cm, etc. |
| CT axial coverage | 4 cm |
| CT maximum slices per rotation | 160 |
| CT spatial resolution | 0.22 mm |
| PET effective sensitivity @20 cm phantom | 97 / 148 cps/ |
| PET effective sensitivity @35 cm phantom | 170.4 / 259.3 cps/ |
| PET effective peak NECR @20 cm phantom | 2,327 / 3,526 kcps |
| PET effective peak NECR @35 cm phantom | 4,059 / 6,150 kcps |
Dose
| CT kV settings | 60, 70, 80, 100, 120, 140 kV |
|---|---|
| CT tube current range | 10-833 mA (1 mA increments) |
Power
| Equivalent tube anode storage capacity | 34 MHU |
|---|
Reconstruction
| PET reconstruction | DPR deep learning plus OSEM TOF + PSF |
|---|---|
| CT reconstruction | AIIR deep-learning iterative reconstruction |
Regulatory
| U.S. FDA 510(k) | K241585, cleared 30 August 2024, product code KPS |
|---|
Applications
- 1Oncology staging and small-lesion detection (18F-FDG, 68Ga-PSMA, 68Ga-FAPI)
- 2Cardiac and myocardial perfusion molecular imaging
- 3Neurology and high-resolution brain imaging
- 4Theranostics and novel-tracer research
- 5Pediatric imaging at reduced dose
- 6Infection and inflammation imaging
- 7Dynamic and quantitative whole-body PET research
Application video
No application video published yet.
We record application walk-throughs for buyers on request — ask us for a live demo or a custom video of this product in operation.
Request an application videoHow we supply this product
We are a China-based export and sourcing company. This product is supplied by us under our own programme — we buy it from the production base, inspect it, and ship to you. It is not sold to you through any third party.
Quote & specification
Send quantity, destination and certification needs. We confirm the exact configuration, voltage/plug variant and lead time.
Sample & approval
Sample or golden sample for your sign-off; private-label branding, packaging and manual localisation if you need them.
Inspect & ship
Pre-shipment inspection against the agreed specification, then consolidation and shipment on EXW / FOB / CIF / DDP terms.
Need a different configuration, voltage or volume? Send the requirement — we source beyond this catalogue.
Specification verification
Parameters on this page were compiled from production-base technical documentation and verified on 12 Sept 2026, at high confidence. Specifications can change without notice — confirm the current revision with us before ordering. Detailed technical files are available on request.